Industrial Vortex Flow Meters | FMV813 Series
The FMV813 Series Vortex Flow Meter delivers highly reliable volumetric and mass flow measurement for steam, gases, and liquids across demanding industrial environments. Operating on the Karman vortex principle, this instrument features no moving mechanical parts, ensuring zero mechanical wear, exceptional long-term stability, and minimal maintenance requirements.
Equipped with optional integrated temperature and pressure compensation, the FMV813 calculates mass flow directly for saturated or superheated steam and compressed air without requiring external flow computers. Available in wafer and flanged process connections with dual pulse, 4-20mA, and RS485 Modbus output options.
Description
Reliable Steam and Gas Flow Measurement Built for Industrial Demands
Accurate steam and gas flow metering is essential for energy management, boiler monitoring, and process efficiency. The FMV813 Series Vortex Flow Meter provides a robust solution designed to perform under tough process conditions, including high temperatures up to +300°C and fluctuating line pressures.
+-----------------------------------------------------------------+
| FMV813 OPERATING PRINCIPLE |
| |
| Fluid Flow ---> [ Shedder Bar ] ---> ( Vortex ) ( Vortex )|
| (Bluff) \ / |
| Piezo Sensor |
+-----------------------------------------------------------------+
Solving Common Industrial Metering Pain Points
-
Pressure & Temperature Fluctuations: In steam and compressed air systems, density changes directly impact measurement accuracy. The FMV813 integrated T&P compensation dynamically calculates real-time mass flow (kg/h or t/h), eliminating inaccuracies caused by line pressure drops.
-
High Maintenance & Mechanical Wear: Traditional mechanical meters suffer from bearing wear, calibration drift, and paddle wheel failures. The FMV813 contains no moving mechanical parts, eliminating mechanical wear and drastically reducing downtime.
-
Vibration Interference: Industrial pipe networks often experience ambient vibration from pumps and compressors. Advanced anti-vibration sensor heads paired with signal-filtering electronics isolate true vortex frequencies from background plant noise.
-
Complex Pipeline Retrofits: Flexible installation options—including compact wafer-type clamping and direct flange mounting—allow easy integration into existing pipeline configurations.
Key Applications
-
Steam Management: Boiler outlet monitoring, saturated steam distribution, and superheated steam metering.
-
Compressed Air & Industrial Gases: Mass flow monitoring of compressed air, nitrogen (N2), argon (Ar), and oxygen (O2).
-
Liquid Processing: Conductive and non-conductive liquids, demineralized water, and high-temperature thermal fluids.
Features
-
Karman Vortex Principle: Delivers wide turndown ratios, high repeatability, and long-term signal stability without moving components.
-
Integrated Temperature & Pressure Compensation: Built-in RTD temperature sensor and dynamic pressure transducer provide direct mass flow computation for steam and gases.
-
High-Temperature Capability: Standard models handle process temperatures up to +260°C, with high-temp configurations rated up to +300°C.
-
Anti-Vibration Signal Processing: Advanced descrambling circuitry and anti-vibration sensor heads filter out mechanical pipeline noise.
-
Precision Cast Stainless Steel Body: Corrosion-resistant SS304/SS316 housing crafted via precision casting for harsh process environments.
-
Versatile Communications: Supports pulse output, 3-wire 4-20mA analog output, RS485 Modbus, and optional HART protocol.
-
Flexible Power Options: Standard 24V DC power input with optional 3.6V lithium battery backup offering 2+ years of continuous field operation.
-
Dual Connection Styles: Available in compact Wafer (pair clamp) or Flanged configurations ranging from DN15 to DN300.
Specification
| Parameter | Specification Details |
| Model |
FMV813 Series Industrial Vortex Flow Meter |
| Measurable Media |
Steam (Saturated & Superheated), Compressed Air, Industrial Gases, Liquids |
| Nominal Diameters |
DN15 to DN300 (1/2 inch to 12 inch) |
| Measurement Accuracy |
Gas/Steam (Uncompensated): ±1.5% (DN15-DN25), ±1.0% (DN32-DN200)
T&P Compensated Type: ±1.5% (DN25-DN300)
Liquid (Uncompensated): ±1.0% (DN15-DN300) |
| Turndown Ratio |
8:1 (Standard, subject to medium density) |
| Medium Temperature Range |
-40°C to +260°C (Standard) / -40°C to +300°C (High Temperature) |
| Output Signals |
Frequency Pulse (Low ≤ 1V, High ≥ 6V), 4-20mA Analog (Load ≤ 300 Ω) |
| Digital Communication |
RS485 Modbus, HART Protocol (Optional) |
| Power Supply |
24V DC ±5% or 3.6V DC Lithium Battery (Battery lifespan > 2 years) |
| Wetted Materials |
Precision Cast Stainless Steel SS304 / SS316 |
| Process Connections |
Wafer Type (Pair Clamp) or Flanged Type (EN 1092-1 / ANSI / JIS) |
| Electrical Interface |
M20 x 1.5 Internal Thread |
FAQ
Q: Why do I need temperature and pressure compensation for steam measurement?
A: Steam is a compressible fluid whose density fluctuates significantly with changes in line temperature and pressure. A standard vortex meter only measures volumetric flow (m^3/h). Integrated temperature and pressure compensation dynamically recalculates steam density in real time, converting volume into accurate mass flow (kg/h or t/h).
Q: What pipe size (DN) do I need for my steam application?
A: Vortex meters depend on fluid velocity to generate measurable vortices. Sizing should be based on your actual volumetric or mass flow rate rather than existing pipe size alone. If your pipeline velocity is low, install pipe reducers to step down the meter size (e.g., placing a DN32 meter in a DN50 line) to ensure reliable measurement across your operational range.
Q: What straight pipe runs are required upstream and downstream?
A: To ensure a fully developed velocity profile, install the meter with a minimum of 10 to 15 pipe diameters (10D-15D) of straight pipe upstream and 5 pipe diameters (5D) downstream. If control valves or elbows are located upstream, longer straight runs (20D-40D) or flow conditioners are recommended.
Q: How does the FMV813 handle plant vibration?
A: The FMV813 uses a specialized piezoelectric stress sensor paired with an anti-vibration sensor head and digital descrambling circuitry. This combination filters out mechanical plant vibration, preventing false pulse readings during low-flow conditions.
Q: Can the FMV813 operate without external main power?
A: Yes. The meter can be ordered with a high-capacity 3.6V lithium battery pack that provides over two years of continuous operation, making it ideal for remote field installations lacking 24V DC wiring.